Reb Research Environmental Equipment & Supplies
18 equipment items found
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Pt-CeO or Pt-alumina catalysts that remove unwanted H2 by combining it with oxygen. This is best done in the presence of air but the CeO version also works in nitrogen or inert gases. Uncoated catalyst works at 20°C to 600°C. Teflon coated catalyst works to -5°C. This is often used aboard submarines where battery-hydrogen is a safety hazzard. See our essay on ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
High temperature, three point thermocouple, 24" long by 1/8" or 16" x 1/16" OD; K type, inconel shieth. Measure temperature at three points inside a reactor. Temperature is measured at the thermocouple tip, at 4" up, and at 8" ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Ammonium-EDDS (Ethylenediamine-N,N'-disuccinic acid) soap 10%. Biodegradable, and non-toxic heavy metal chelator. Used to remove heavy metals (lead, arsenic, chrome, iron, and nickel) from surfaces including walls, floors, desks, and silicon wafers. Has also been used as an antidote to lead ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
For use at higher pressures or temperatures; operation between 200° C and 700° C; pressure to 350 psi at 400° C; Selectivity to hydrogen: 100%. Each membrane tube is .125" diameter by 7" tall. Inconel construction. Reactor shell is 12" tall x 1" diameter; 1/4" Swagelok connections for bleed, and pure H2 outlet; allows easy addition and removal of catalyst. For extra length, to 20" add ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Niobium-based hydrogen permeation membranes 3/8" x .007" wall coated with 1.6/u Pd 4" or 6" standard lengths. Other lengths available. Graphite ferrules and modified swageloks sold ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Uniform Temperature Membrane Test Rig used to test hydrogen permeation in disc or tube (specify) membranes at pressures up to 300 psi and temperatures up to 450 C. Stainless Steel, 1.75" OD with an interior volume 1.4" ID" by 8" or 18" long, sealed by a copper or graphite gasket. A counter flow annulus provides improved temperature uniformity. Membranes attach by swagelock and graphite ferrules, ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Graphite-steel or copper gaskets for 2 3/8" or 4" Conflat flanges. Used for sealing conflat flanges at pressures up to 350 psi and temperatures up to 400 C.Graphite ferrules; used for high temperatuere membranes. O-rings are for lower ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Uniform heat, vertical tube furnace with temperature controller. For use with 20" membrane reactor, or for general laboratory applications. Maximum use to 1100°C, 120 or 240 Volt operation; 10" x 15" x20" tall; heated zone is 1.75" ID by 12" tall. Extra windings at the ends of the heated zone make the temperature more uniform. See safety certification . Includes a secondary K-thermocouple ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Used to evaluate catalysts for use in membrane reactors. Available in low temperature (200-450° C) or high temperature (200-700° C) versions, stainless steel or inconel construction. Customized solutions are also ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
3 point thermocouple in a " Thermocouple T". High temperature, three point, K-type thermocouple; 1/8" OD or 1/16" inconel shieth, wires extent from the side through a 3/4" swagelok "T". Allows detailed temperature measurements inside the reactor while not interfering with flow or the ability to add and remove catalyst. Temperature is measured at the thermocouple tip, at 4" up, and at 8" ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Hydrogen generator: Purer hydrogen, cheaper than bottled gas. Example, if you use 1.5 slpm of bottled gas, that's 15 cylinders/month (135 cf size). This is inconvenient and costs about ~$3,000/month. The alternative is this Me100-2 using 15 gal/month of metahnol-water (~$150) and 70kWh of electicity ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Similar to the PS2-GC50 from SAES getter but with somewhat longer life and a dual zone heater for higher purity output. Moreover, it offers twice the life time compared to the PS2-GC50, but no end-of-life indicator. 1/8" VCR output. ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
We off a system to measure the permeation rate for gases through sheets of poymers or metal. The system meets ASTM standards. It is a small volume chamber with a presure sensor good to 0.01 mTorr, a high vacuum valve and a cell that can hold up to 2 atm on the high pressure side and vacuum on the low pressure side. Add gas to one side, vaccum out the otehr side; bake it out because of degassing, ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Tublular Pd-25%Ag membranes 1/8" OD x .003" wall: plain, coated with Pd-grey, or coated with PdCu or PdAu. These are generally sold sealed at one end and brazed to a stainless steel stub at the other. Length=6"+1" stub, 7" total. Selectivity to hydrogen ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Tube bundle containing 72 Pd-Ag membranes 1/8" OD x .003" wall x 18" tall. Sold brazed into a tube sheet with spacers to hold the membranes and promote proper gas flow. For operation at pressures up to 400 psi and temperatures up to 450 ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Higher Pressure Membrane Test Rig, 21" tall by 1.5" outer diameter; 7/8" ID, used to test hydrogen permeation at pressures up to 600 psi and temperatures up to 650 C. Test volume is 18" long, with a counter-flow annulus for improved temperature uniformity. Test volume sealed with a 1" swagelok fitting. Membranes attach to internal holder by swagelock and graphite ferrules, sold separately. Fits ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Swagelok 3/8" unions and caps modified to accomodate the swelling of refractory membranes. Use with and 3/8" graphite ferrules (bleow) and apparatus above for testing brittle hydrogen permeation membranes or membranes that might ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Use for the water gas shift reaction or lower-pressure methanol reforming at 200° C to 450° C operation. Pressure to 200 psi at 400° C. Selectivity to hydrogen: 100%. Each membrane tube is .080" diameter by 7" tall. Stainless steel construction, 10 to 12" tall, 3⁄4" to 1" diameter; 1/4" Swagelok connections for bleed, and pure H2 outlet; allows easy addition and removal of ...